JavaScript seems to be disabled in your browser.
You must have JavaScript enabled in your browser for full functionality of this website.
 

Concrete Anchors & Fasteners is Our Specialty   Questions? Contact Mike   

You have no items in your shopping cart.
Free Shipping
For orders $25
or more within
the USA

1/2" x 12" Stainless Steel Wedge Anchor, 25/Box

   Availability: In Stock
  Questions? Email Mike

$233.00 per Box of 25
    Payment types
Purchase the 1/2" x 12" Stainless Steel Wedge Anchor direct for huge savings; orders will be ready for immediate, same day shipment with free freight.
SKU: WAS1212
  MFG: CONFAST® , CONFAST®

 

Customer Reviews

CONFAST® - 1/2" x 12" Stainless Steel Wedge Anchor

The 1/2" x 12" Stainless Steel Wedge Anchor (25 pcs per box) are designed for attaching to concrete. Every order will be shipped directly from the Cleveland, Ohio warehouse for delivery in 1 to 3 days.

  • Bit size 1/2"
  • Minimum embedment 2-1/4"
  • Thread Length 4"
  • 304 stainless steel for use in wet environments
  • Not acceptable for use in a vibratory load
  • Packaged with 304 stainless steel nuts and washers
  • 1/2" inch diameter x 12" (twelve inches) inch length
  • Must space anchor a minimum of 5" from each other
  • Every order over $25.00 ships for free
Products specifications
Bit Size 1/2"
Minimum Embedment 2-1/4"
Thread Length 4"
Thread Type 1/2" - 13
2000 PSI Concrete - Pull-Out (lbs.) * 2999
2000 PSI Concrete - Shear (lbs.) * 5564
Type Male
Primary Concrete only
Diameter 1/2"
Length 12"
Material 304 Stainless Steel
Environment Wet
Box Qty 25
Minimum Spacing 5"
Minimum Edge Distance 2-1/2"
Maximum Fixture Thickness 9-1/4"
Minimum Fixture Hole Diameter (In Place) 5/8"
Minimum Fixture Hole Diameter (Hole Spotted) 1/2"
Length ID Code T
Maximum Torque 50 - 60 ft./lbs.
Wrench Size For Nut 3/4"
Length Measurement End to End
Brand Name CONFAST®

Applications
The 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is made from (three zero four) 304 Stainless Steel. This anchor is designed for use in concrete only, and should never be used in block or brick base material.

Environment
The anchor is designed for use in an outdoor, wet environment.

Hole Diameter/Bit Diameter
The 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor requires a 1/2" hole to be drilled in the base material (concrete only). The hole should be drilled with carbide tipped bit that meets ANSI standards and used in a hammer drill.

Diameter of Anchor
The diameter of the 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is 1/2".

Length Anchor
The length of the anchor is 12" (twelve inches), and is measured as an overall length of the anchor from end to end.

Thread Type
The threads on the 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor are national coarse threads that measures 1/2" with 13 threads per inch, commonly referred to as 1/2"-13.

Thread Length
The length of the threads on the anchor is 4" in length.

Packaging
The 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is packaged with 25 pieces per box and is packaged with the correct number and diameter of nuts and washers.

Minimum Embedment
The anchor minimum embedment into the concrete is 2-1/4". Therefore, the anchor must be installed so that a minimum of 2-1/4" of the anchor is embedded into the concrete.

Maximum Fixture Thickness
The maximum fixture thickness or the maximum thickness of the material being fastened for a 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is 9-1/4". This will ensure that the minimum embedment of 2-1/4" will be met.

Fixture Hole Diameter
The hole in the fixture or material being fastened must be larger than the designated diameter of the anchor . The 1/2" diameter anchor requires the hole in the fixture to be 5/8".

Wrench Size
The size of the wrench required to turn the nut to set the 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is 3/4".

Torque Value
To be set properly in the concrete, the anchor must be torqued to between 50 - 60 ft./lbs.

Spacing between Anchors
Each 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor must be spaced a minimum distance of 5" from each other when measured center to center.

Edge Distance
It is very important not to install the anchor any closer than 2-1/2" from an unsupported edge of concrete.

Markings
The 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is stamped with the letter T on the threaded end to allow inspection of the anchor after installation. The letter "T" designates an overall length of the anchor as between 12" up to, but not including 13" in length.

Holding Values - Ultimate Load Values in 2000 PSI Concrete

1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor Size

Minimum Embedment

Pull-Out (lbs.)

Shear (lbs.)

1/2" x 12" (twelve inches)

2-1/4"

2999

5564


Product Information

Description

Part number

Quantity per Box

1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor

WAS1212

25

Installing a 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor
  1. Drill a 1/2" hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15.
  2. Drill the hole a 1/2" deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 2-1/4" is met.
  3. The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor is 5/8".
  4. Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb.
  5. Put the nut and washer on the 1/2" x 12" (twelve inches) Stainless Steel Wedge Anchor, making sure the nut is on the last threads; this will protect the threads from damage when the wedge anchor is hammered into the hole and into the concrete.
  6. Insert the anchor through the hole in the fixture and into the hole in the base material.
  7. This should be a very tight fit. Then use a hammer to complete the installation until the nut and washer are tight against the fixture. It is important that the threads go below the surface of either the base material or the fixture.
  8. Turn the nut clockwise on the anchor until finger tight.
  9. Using a 3/4" wrench, turn the nut 3 to 4 times until snug or until the proper torque value of 50 - 60 ft./lbs. is reached.
  10. Always use proper personal protective equipment per manufacturer's and OSHA instructions.

*
*
*

* The figures above indicate average ultimate tension and shear failure values. A safety factor of 4:1 or 25% of ultimate value is generally accepted as a safe working load. Reference should always be made to applicable codes.



These bits work with the selected anchor
Back to product