1" x 9" Hot-Dipped Galvanized Wedge Anchor, 5/Box

   Availability: In Stock
  Questions? Email Mike

$93.15 per Box of 5
    Payment types
Purchase the 1" x 9" Hot-Dipped Galvanized Wedge Anchor direct and save; items are stocked for immediate free shipping from our Ohio warehouse.
SKU: WAG19
  MFG: CONFAST®

 

Customer Reviews

CONFAST® - 1" x 9" Hot-Dipped Galvanized Wedge Anchor

The CONFAST® 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor (5 pcs per box) are designed for fastening to concrete. All orders ship immediately from the Cleveland, Ohio warehouse for delivery in 1 to 3 days.

  • Bit size 1"
  • Minimum embedment 4-1/2"
  • Thread Length 4"
  • 304 stainless steel clip
  • Hot-Dipped Galvanized for use in moist environments
  • For use in non-vibratory loading applications
  • Packaged with hot-dipped galvanized nuts and washers
  • 1" thick x 9" (nine inches) overall length
  • Spacing between anchors is a minimum of 10 anchor diameters
  • Free shipping on orders over $25.00
Products specifications
Bit Size 1"
Minimum Embedment 4-1/2"
Thread Length 4"
Thread Type 1" - 8
2000 PSI Concrete - Pull-Out (lbs.) * 7329
2000 PSI Concrete - Shear (lbs.) * 17712
Type Male
Primary Concrete only
Diameter 1"
Length 9"
Material Hot-Dipped Galvanized
Environment Damp
Box Qty 5
Minimum Spacing 10"
Minimum Edge Distance 5"
Maximum Fixture Thickness 3-1/2"
Minimum Fixture Hole Diameter (In Place) 1-1/4"
Minimum Fixture Hole Diameter (Hole Spotted) 1"
Length ID Code P
Maximum Torque 250 - 300 ft./lbs.
Wrench Size For Nut 1-1/2"
Length Measurement End to End
Brand Name CONFAST®

Applications
The 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is made from Carbon Steel, and is Hot-Dipped Galvanized. This anchor is designed for use in concrete only, and should never be used in block or brick base material.

Environment
The anchor is designed for use in an outdoor, damp environment.

Hole Diameter/Bit Diameter
The 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor requires a 1" hole to be drilled in the base material (concrete only). The hole should be drilled with carbide tipped bit that meets ANSI standards and used in a hammer drill.

Diameter of Anchor
The diameter of the 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is 1".

Length Anchor
The length of the anchor is 9" (nine inches), and is measured as an overall length of the anchor from end to end.

Thread Type
The threads on the 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor are national coarse threads that measures 1" with 8 threads per inch, commonly referred to as 1"-8.

Thread Length
The length of the threads on the anchor is 4" in length.

Packaging
The 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is packaged with 5 pieces per box and is packaged with the correct number and diameter of nuts and washers.

Minimum Embedment
The anchor minimum embedment into the concrete is 4-1/2". Therefore, the anchor must be installed so that a minimum of 4-1/2" of the anchor is embedded into the concrete.

Maximum Fixture Thickness
The maximum fixture thickness or the maximum thickness of the material being fastened for a 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is 3-1/2". This will ensure that the minimum embedment of 4-1/2" will be met.

Fixture Hole Diameter
The hole in the fixture or material being fastened must be larger than the designated diameter of the anchor . The 1" diameter anchor requires the hole in the fixture to be 1-1/4".

Wrench Size
The size of the wrench required to turn the nut to set the 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is 1-1/2".

Torque Value
To be set properly in the concrete, the anchor must be torqued to between 250 - 300 ft./lbs.

Spacing between Anchors
Each 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor must be spaced a minimum distance of 10" from each other when measured center to center.

Edge Distance
It is very important not to install the anchor any closer than 5" from an unsupported edge of concrete.

Markings
The 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is stamped with the letter P on the threaded end to allow inspection of the anchor after installation. The letter "P" designates an overall length of the anchor as between 9" up to, but not including 9-1/2" in length.

Holding Values - Ultimate Load Values in 2000 PSI Concrete

1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor Size

Minimum Embedment

Pull-Out (lbs.)

Shear (lbs.)

1" x 9" (nine inches)

4-1/2"

7329

17712


Product Information

Description

Part number

Quantity per Box

1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor

WAG19

5

Installing a 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor
  1. Drill a 1" hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15.
  2. Drill the hole a 1/2" deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 4-1/2" is met.
  3. The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor is 1-1/4".
  4. Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb.
  5. Put the nut and washer on the 1" x 9" (nine inches) Hot-Dipped Galvanized Wedge Anchor, making sure the nut is on the last threads; this will protect the threads from damage when the wedge anchor is hammered into the hole and into the concrete.
  6. Insert the anchor through the hole in the fixture and into the hole in the base material.
  7. This should be a very tight fit. Then use a hammer to complete the installation until the nut and washer are tight against the fixture. It is important that the threads go below the surface of either the base material or the fixture.
  8. Turn the nut clockwise on the anchor until finger tight.
  9. Using a 1-1/2" wrench, turn the nut 3 to 4 times until snug or until the proper torque value of 250 - 300 ft./lbs. is reached.
  10. Always use proper personal protective equipment per manufacturer's and OSHA instructions.

1" x 12" hot dipped galvanized wedge anchor - concrete - dock leveler

*
*
*

* The figures above indicate average ultimate tension and shear failure values. A safety factor of 4:1 or 25% of ultimate value is generally accepted as a safe working load. Reference should always be made to applicable codes.



These bits work with the selected anchor
Back to product