JavaScript seems to be disabled in your browser.
You must have JavaScript enabled in your browser for full functionality of this website.
 

Concrete Anchors & Fasteners is Our Specialty   Questions? Contact Mike   

You have no items in your shopping cart.
Free Shipping
For orders $25
or more within
the USA

5/16" x 2-3/4" Stainless Steel U.S. Made Thunderstud Wedge Anchor, 100/Box

   Availability: In Stock
  Questions? Email Mike

$186.00 per Box of 100
    Payment types
Purchase direct on-line, 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor. Qualifies under the Buy America Act (BAA) and freight is free.
SKU: TSS516234
Buy America Act Compliance Logo

 


 

Customer Reviews

ThunderStud ® - 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor

The American made 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor (100 pcs per box) are used for attaching fixtures to solid concrete in wet outdoor environments. Every order ships directly from the Cleveland, Ohio for delivery in 1 to 3 days.

  • Bit size 5/16"
  • Minimum embedment 1-1/8"
  • Thread Length 1-1/8"
  • Designed for use in wet outdoor environments
  • Not for use in vibratory loading applications
  • BAA qualified concrete wedge anchor
  • 5/16" inch in diameter x 2-3/4" inches in length
  • Must space anchors a minimum of 3-1/8" from each other
  • Free shipping on all orders over $25.00
Products specifications
Bit Size 5/16"
Minimum Embedment 1-1/8"
Thread Length 1-1/8"
Thread Type 5/16" - 18
2000 PSI Concrete - Pull-Out (lbs.) * 1285
2000 PSI Concrete - Shear (lbs.) * 1585
Type Male
Primary Concrete only
Diameter 5/16"
Length 2-3/4"
Material 303 Stainless Steel
Environment Wet
Box Qty 100
Minimum Edge Distance 1-9/16"
Maximum Fixture Thickness 5/8"
Minimum Fixture Hole Diameter (In Place) 7/16"
Minimum Fixture Hole Diameter (Hole Spotted) 5/16"
Length ID Code C
Maximum Torque 15 - 20 ft./lbs.
Wrench Size For Nut 1/2"
Length Measurement End to End
Country American Made
Brand Name ThunderStud

Applications
The 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is made from (three zero three) 303 Stainless Steel and meets the Buy America Act (BAA). This anchor is designed for use in concrete only, and should never be used in block or brick base material.

Environment
The anchor is designed for use in an outdoor, wet environment.

Hole Diameter/Bit Diameter
The 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor requires a 5/16" hole to be drilled in the base material (concrete only). The hole should be drilled with carbide tipped bit that meets ANSI standards and used in a hammer drill.

Diameter of Anchor
The diameter of the 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is 5/16".

Length Anchor
The length of the anchor is 2-3/4", and is measured as an overall length of the anchor from end to end.

Thread Type
The threads on the 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor are national coarse threads that measures 5/16" with 18 threads per inch, commonly referred to as 5/16"-18.

Thread Length
The length of the threads on the anchor is 1-1/8" in length.

Packaging
The 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is packaged with 100 pieces per box and is packaged with the correct number and diameter of nuts and washers.

Minimum Embedment
The anchor minimum embedment into the concrete is 1-1/8". Therefore, the anchor must be installed so that a minimum of 1-1/8" of the anchor is embedded into the concrete.

Maximum Fixture Thickness
The maximum fixture thickness or the maximum thickness of the material being fastened for a 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is 5/8". This will ensure that the minimum embedment of 1-1/8" will be met.

Fixture Hole Diameter
The hole in the fixture or material being fastened must be larger than the designated diameter of the anchor . The 5/16" diameter anchor requires the hole in the fixture to be 7/16".

Wrench Size
The size of the wrench required to turn the nut to set the 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is 1/2".

Torque Value
To be set properly in the concrete, the anchor must be torqued to between 15 - 20 ft./lbs.

Spacing between Anchors
Each 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor must be spaced a minimum distance of 3-1/8" from each other when measured center to center.

Edge Distance
It is very important not to install the anchor any closer than 1-9/16" from an unsupported edge of concrete.

Markings
The 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is stamped with the letter C on the threaded end to allow inspection of the anchor after installation. The letter "C" designates an overall length of the anchor as between 2-1/2" up to, but not including 3" in length.

Holding Values - Ultimate Load Values in 2000 PSI Concrete

5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor Size

Minimum Embedment

Pull-Out (lbs.)

Shear (lbs.)

5/16" x 2-3/4"

1-1/8"

1285

1585


Product Information

Description

Part number

Quantity per Box

5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor

TSS516234

100

Installing a 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor
  1. Drill a 5/16" hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15.
  2. Drill the hole a 1/2" deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 1-1/8" is met.
  3. The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor is 7/16".
  4. Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb.
  5. Put the nut and washer on the 5/16" x 2-3/4" Stainless Steel Thunderstud Wedge Anchor, making sure the nut is on the last threads; this will protect the threads from damage when the wedge anchor is hammered into the hole and into the concrete.
  6. Insert the anchor through the hole in the fixture and into the hole in the base material.
  7. This should be a very tight fit. Then use a hammer to complete the installation until the nut and washer are tight against the fixture. It is important that the threads go below the surface of either the base material or the fixture.
  8. Turn the nut clockwise on the anchor until finger tight.
  9. Using a 1/2" wrench, turn the nut 3 to 4 times until snug or until the proper torque value of 15 - 20 ft./lbs. is reached.
  10. Always use proper personal protective equipment per manufacturer's and OSHA instructions.

*
*
*

* The figures above indicate average ultimate tension and shear failure values. A safety factor of 4:1 or 25% of ultimate value is generally accepted as a safe working load. Reference should always be made to applicable codes.



These bits work with the selected anchor